Total Dynamic Head Calculator
Result
— ft
Fill in the inputs, then press Calculate.
Calculation results are estimates based on the inputs and assumptions shown. Verify equipment selection against current manufacturer data and applicable requirements. Do not rely solely on this calculator for safety-critical design decisions. See Disclaimer
This calculator can estimate straight-pipe friction loss for water using the Darcy-Weisbach equation, or accept a friction loss you already know. Losses through fittings and valves can be calculated from a total loss coefficient ΣK that you supply, or entered as a known head loss.
Formula and methodology
Total dynamic head is the total head, in feet of fluid, that a pump must add at the required operating flow:
TDH = Static/Elevation Head + Pressure Head + Pipe Friction Head + Minor Losses
Pipe friction and minor losses each come from exactly one source: either the calculation or your known value — never both.
Pressure Head (ft) = Pressure (psi) × 2.31 / Specific Gravity
- 2.31 is approximately the feet of water head corresponding to 1 psi under standard conditions. Dividing by specific gravity adjusts for fluids of different density; 1.0 represents water.
- Static / elevation head is discharge elevation minus source liquid-surface elevation. It is negative when the discharge is below the source. It is not suction lift, suction pressure, NPSH or pump-centerline elevation.
- Pressurized or otherwise more complex suction/discharge systems may require additional terms (suction pressure, velocity effects and others) that this simplified setup does not model.
Straight-pipe friction (Darcy-Weisbach)
hf = f × (L / D) × V² / (2g)
- Flow is converted with 1 US gallon = 231 in³ = 0.13368 ft³ and 60 s per minute. Inside diameter is converted from inches to feet, so L/D uses feet throughout.
- Velocity V = Q / A, with A = πD²/4 from the actual inside diameter (not nominal size).
- Reynolds number Re = V·D / ν, with V in ft/s, D in ft and kinematic viscosity ν in ft²/s. ν is the viscosity of liquid water at the temperature you enter (see below).
- Laminar (Re < 2300): f = 64 / Re. Turbulent (Re ≥ 4000): Swamee-Jain, f = 0.25 / [log10(ε/(3.7D) + 5.74/Re0.9)]².
- Transitional (2300 ≤ Re < 4000): flow is unstable here and no single friction factor is reliable. The calculator shows an estimate by linear interpolation between 64/2300 and the Swamee-Jain value at Re = 4000, and labels it as such. The interpolation is used only to give a continuous estimate through this region; it is not a published physical law.
- g = 32.1740 ft/s² (standard gravity).
- Absolute roughness ε depends on the material, age and condition of the pipe. Enter a value from the manufacturer or a reference you trust.
Minor losses from K values
h_minor = ΣK × V² / (2g)
Each fitting or component has a loss coefficient K. Add them up and enter the total, ΣK. The calculator multiplies it by the velocity head V²/(2g) of the same pipe used for friction. That is only correct when every K value belongs to a component in that pipe size; components in a different pipe size have a different velocity. K-based losses need a pipe velocity, so they are only available when pipe friction is calculated. Fitting presets are not provided yet.
This calculation estimates friction loss through the straight pipe entered above. Fittings, valves, strainers, filters and other components can add additional losses unless those losses are included separately.
Worked example
An illustrative case: water at 50 °F, 150 gpm, through 300 ft of straight pipe with a 3.068 in inside diameter and an absolute roughness of 0.00015 ft. The discharge is 35 ft above the source surface, 30 psi is required at the outlet, and the fittings in this pipe add up to ΣK = 4.5.
- Pressure head: 30 × 2.31 / 1.0 = 69.3 ft
- Water viscosity at 50 °F: 1.410e-5 ft²/s
- Velocity: 6.51 ft/s · Reynolds number ≈ 118,000 (turbulent)
- Darcy friction factor (Swamee-Jain): 0.0204
- Straight-pipe friction head: 15.8 ft
- Velocity head V²/(2g): 0.659 ft → minor loss 4.5 × 0.659 = 3.0 ft
- TDH = 35 + 69.3 + 15.8 + 3.0 ≈ 123.0 ft
Next, check 150 gpm at about 123.0 ft against the manufacturer's pump performance curve. TDH alone does not determine the correct pump.
Technical notes
Water-temperature viscosity basis
Automatic friction is for liquid water only. Kinematic viscosity is taken from Linsley, Kohler & Paulhus (1982), Hydrology for Engineers, 3rd ed., Table A-2, using linear interpolation between adjacent table points. Supported range: 32–200 °F; values outside it are not extrapolated.
| °F | ν (×10⁻⁵ ft²/s) |
|---|---|
| 32 | 1.931 |
| 40 | 1.664 |
| 50 | 1.410 |
| 60 | 1.217 |
| 70 | 1.058 |
| 80 | 0.930 |
| 90 | 0.826 |
| 100 | 0.739 |
| 120 | 0.609 |
| 140 | 0.514 |
| 160 | 0.442 |
| 180 | 0.386 |
| 200 | 0.341 |
Changing specific gravity adjusts pressure head only. It does not change the viscosity, so automatic friction does not model other fluids.
Darcy vs. Fanning
This calculator uses the Darcy friction factor, not the Fanning friction factor.
Velocity notice
When the pipe velocity reaches 25 ft/s or more, a notice suggests checking the flow and inside diameter. 25 ft/s is a sanity-check threshold only — it is not a universal design limit, not a code requirement and not a maximum permitted velocity, and it does not change the calculation. Acceptable velocities depend on the system and the standard that applies.
Pump selection
TDH is one point: head at one flow. Choosing a pump still requires the manufacturer's pump curve.
Related calculators
Well Pump Size Calculator
Estimate the GPM and total dynamic head a residential well pump must deliver.
Friction Loss Calculator
Calculate straight-pipe friction loss for water in feet of head and psi.
Pool Pump Size Calculator
Find the GPM and total dynamic head a pool pump must deliver from pool volume and turnover time.