Skip to content
Pump Calculators

Head & Pressure

Pool Pump Size Calculator

Find the duty point a pool pump must meet: the flow needed to turn your pool over in the time you choose, and the total dynamic head of the circulation plumbing.

Required flow
gal

The time to circulate the full pool volume once. 8–10 hours is common industry practice; check your local health code or builder's specification.

hours

Elevation the pump must lift water (e.g. pump above the pool water surface). Use 0 if the pump is at water level.

ft
Pipe friction loss

Total straight length of suction and return pipe.

ft

Actual inside diameter, not nominal size.

in

From the pipe manufacturer or a reference you trust. Use 0 for hydraulically smooth.

ft

Optional. Blank uses 60 °F. Range 32–200 °F.

°F
Minor losses (fittings, valves)

Sum of K values for all elbows, valves and fittings. Blank counts as 0. Filter and heater resistance are not included — add them here or as a known loss.

How pool pump sizing works

A pool pump is sized by its duty point: a required flow and the total dynamic head (TDH) the plumbing creates at that flow. The required flow comes from the pool volume and the turnover time — the time to circulate the full volume once:

Flow (gpm) = pool volume (gal) ÷ turnover time (h) ÷ 60

TDH combines the elevation the pump must lift water, straight-pipe friction (Darcy-Weisbach, the same verified engine as our Total Dynamic Head Calculator) and minor losses from fittings and valves. A pool loop returns to the pool at atmospheric pressure, so there is no pressure term. Filter, heater and cleaner pressure drops are equipment-specific and are not modelled — add them from manufacturer data to the minor-loss input.

Worked example

A 20,000 gal pool with an 8 h turnover needs 20000 ÷ 8 ÷ 60 = 41.7 gpm. With 5 ft of elevation head, 150 ft of pipe at 1.5 in inside diameter and 0.000005 ft roughness, water at 80 °F, and ΣK = 10: friction ≈ 19.3 ft, minor losses ≈ 8.9 ft, for a duty point of 41.7 gpm @ 33.2 ft TDH.

Full formula details and sources are on the methodology page. Once you have a duty point, the Pump Horsepower Calculator estimates the power required.