Head & Pressure
Pool Pump Size Calculator
Find the duty point a pool pump must meet: the flow needed to turn your pool over in the time you choose, and the total dynamic head of the circulation plumbing.
How pool pump sizing works
A pool pump is sized by its duty point: a required flow and the total dynamic head (TDH) the plumbing creates at that flow. The required flow comes from the pool volume and the turnover time — the time to circulate the full volume once:
Flow (gpm) = pool volume (gal) ÷ turnover time (h) ÷ 60
TDH combines the elevation the pump must lift water, straight-pipe friction (Darcy-Weisbach, the same verified engine as our Total Dynamic Head Calculator) and minor losses from fittings and valves. A pool loop returns to the pool at atmospheric pressure, so there is no pressure term. Filter, heater and cleaner pressure drops are equipment-specific and are not modelled — add them from manufacturer data to the minor-loss input.
Worked example
A 20,000 gal pool with an 8 h turnover needs 20000 ÷ 8 ÷ 60 = 41.7 gpm. With 5 ft of elevation head, 150 ft of pipe at 1.5 in inside diameter and 0.000005 ft roughness, water at 80 °F, and ΣK = 10: friction ≈ 19.3 ft, minor losses ≈ 8.9 ft, for a duty point of 41.7 gpm @ 33.2 ft TDH.
Full formula details and sources are on the methodology page. Once you have a duty point, the Pump Horsepower Calculator estimates the power required.