These calculators are meant to make common pump calculations easier to do and easier to understand. This page explains the principles behind them.

Established relationships

Formulas come from established engineering relationships used in pump and fluid-system work, not from invented shortcuts.

Units and conversions

Units are shown next to every input and result, and unit conversions are checked.

Disclosed assumptions

When a calculator assumes something — for example, that the fluid is water — it says so. Values that have not been verified are flagged rather than guessed.

Theoretical vs. real-world

Where it matters, results distinguish theoretical values from estimated real-world values, which include losses and inefficiencies.

Sensible precision

Results are rounded to a level of precision the inputs can actually support.

Manufacturer data still matters

Selecting an actual pump requires the manufacturer's pump curves and documentation. A calculated operating point is where that comparison starts.

Pipe friction (Total Dynamic Head calculator)

Straight-pipe friction uses the Darcy-Weisbach equation, hf = f × (L/D) × V²/(2g), with the Darcy friction factor (not the Fanning friction factor). The Reynolds number, Re = V·D/ν, decides the flow regime. Laminar flow (Re < 2300) uses f = 64/Re; turbulent flow (Re ≥ 4000) uses the Swamee-Jain approximation of the Colebrook equation, with a warning outside its stated validity range. Between 2300 and 4000, linear interpolation is used only to provide a continuous estimate through the transition region; it is labelled as an estimate.

Water viscosity comes from a published table (Linsley, Kohler & Paulhus, Hydrology for Engineers, 3rd ed., Table A-2) for 32–200 °F, interpolated linearly and never extrapolated. Minor losses use h = ΣK × V²/(2g) with K values you supply.

Limits

Results are estimates based on your inputs and the stated assumptions; they are not guaranteed to be accurate or suitable for every application. They are not a substitute for professional engineering judgment when safety, code compliance or expensive equipment is involved, and they do not determine code compliance. See the disclaimer.