Well Pump Size Calculator
Pump duty point
— gpm @ — ft
Fill in the inputs, then press Calculate.
Calculation results are estimates based on the inputs and assumptions shown. Verify equipment selection against current manufacturer data and applicable requirements. Do not rely solely on this calculator for safety-critical design decisions.
How to size a well pump
A well pump is chosen for a duty point: the flow it must deliver (GPM) at the total dynamic head (TDH) it must overcome. This calculator works out both. Horsepower alone does not determine the right pump, and neither does the total depth of the well.
What GPM does my well pump need?
Penn State Extension notes that most single-family homes should have at least about 6 GPM available, and publishes this table of suggested minimum flows (attributed to the Private Water Systems Handbook). Only these combinations are used; any other home should enter its flow directly.
| Bedrooms | 1 bath | 1.5 bath | 2 bath | 3 bath |
|---|---|---|---|---|
| 2 | 6 gpm | 8 gpm | 10 gpm | — |
| 3 | 8 gpm | 10 gpm | 12 gpm | — |
| 4 | 10 gpm | 12 gpm | 14 gpm | 16 gpm |
| 5 | — | 13 gpm | 15 gpm | 17 gpm |
| 6 | — | — | 16 gpm | 18 gpm |
These are suggested minimum flows — not a guaranteed peak demand, a code requirement or a pump size. Larger homes, unusual fixtures, irrigation, water treatment equipment, livestock or several uses at once may need a separately determined flow rate.
Why pumping water level matters
The pump lifts water from where the water surface sits while pumping, not from the bottom of the well.
- Static water level: depth from the reference point at the wellhead to the water surface when the well is at rest.
- Drawdown: additional drop in water level while the well is being pumped.
- Pumping water level = static water level + drawdown. If you have a measured pumping level, enter it directly instead — the two methods are never added together.
Total drilled depth is not the same as pumping lift and does not directly determine pump TDH. If you enter it, it is only used to catch a pumping level deeper than the well.
What is well yield?
Penn State Extension defines well yield as the maximum pumping rate that can be sustained without lowering the water level below the pump intake. Use the sustainable yield from your well log, driller's report or a pumping/yield test; the calculator never estimates it. If the household flow is higher than the yield, the calculator shows both values and a warning rather than lowering the flow. Installing a larger pump does not increase the aquifer's sustainable yield.
How total dynamic head is calculated
TDH = Pumping Water Level + Elevation Rise + Pressure Head + Straight-Pipe Friction + Minor Losses
Pressure Head (ft) = Cut-Out Pressure (psi) × 2.31
- Elevation rise is the vertical distance from the wellhead reference point to the pressure tank or highest required delivery point.
- The cut-out pressure is used, not the average: the pump must be able to reach the switch cut-out pressure or the pressure switch may not shut the pump off normally. Any cut-in/cut-out pair can be entered. 2.31 ft per psi is for water (specific gravity 1.0).
- Straight-pipe friction uses the same Darcy-Weisbach engine as the Total Dynamic Head Calculator (Swamee-Jain friction factor, laminar 64/Re, interpolated transitional estimate), with water viscosity from Linsley, Kohler & Paulhus (1982), Hydrology for Engineers, 3rd ed., Table A-2, 32–200 °F.
- Pipe length is the developed length of the water path — drop pipe, buried service line and other straight delivery pipe — not just the vertical lift, and not automatically the well depth. Use the actual inside diameter, not the nominal size.
- Minor losses are ΣK × V²/(2g) for the total K you supply, or a known head loss. No fitting presets are provided.
How to use GPM and TDH with a pump curve
Find the manufacturer's performance curve for each pump you consider. Locate the required TDH on the head axis and check that the curve delivers at least the required GPM there. Don't choose a pump only because its maximum GPM, maximum head or horsepower appears large enough — the flow it delivers at your head is what matters.
Need to estimate hydraulic power?
Pump Horsepower Calculator
Estimate hydraulic and shaft power from flow, head and efficiency.
Low-yield wells
A low-yield well can sometimes meet total daily household water needs but still fall short during short periods of high demand. Penn State Extension notes that peak demand periods commonly last roughly 30 minutes to 2 hours, and discusses storage as a way to bridge the gap when well yield cannot meet peak demand. Sizing that storage is outside this calculator.
Worked example
A 3-bedroom, 2-bathroom home. Static water level 80 ft, drawdown 40 ft, pressure tank 15 ft above the wellhead, 40/60 psi pressure switch. 250 ft of straight pipe (drop pipe plus service line) with a 1.049 in inside diameter and absolute roughness 0.000005 ft, water at 55 °F, fittings totalling ΣK = 6. Well yield 15 gpm. These pipe values are illustrative inputs, not recommendations.
- Required flow (Penn State table, 3 bed / 2 bath): 12 gpm
- Pumping water level: 80 + 40 = 120.0 ft
- Elevation rise: 15.0 ft
- Pressure head: 60 × 2.31 = 138.6 ft
- Velocity 4.45 ft/s, Reynolds number ≈ 29,600, friction factor 0.0236 → straight-pipe friction 20.8 ft
- Minor losses: 6 × 0.308 = 1.9 ft
- TDH = 120.0 + 15.0 + 138.6 + 20.8 + 1.9 ≈ 296.3 ft
- Well yield 15 gpm ≥ 12 gpm, so the entered yield meets the flow target.
Duty Point = 12 GPM @ 296.3 ft TDH
Take that duty point to manufacturers' pump curves and look for pumps that deliver at least 12 GPM at about 296.3 ft.
Sources / References
- Penn State Extension, “Water System Planning: Estimating Water Needs” — household flow table and well-yield definition. https://extension.psu.edu/water-system-planning-estimating-water-needs
- Penn State Extension, “Using Low-Yielding Wells” — peak demand versus well yield, and storage. https://extension.psu.edu/using-low-yielding-wells
- Swamee, P.K. & Jain, A.K. (1976), “Explicit equations for pipe-flow problems”, J. Hydraulics Div. ASCE 102(5) — turbulent friction factor.
- Darcy-Weisbach equation and the 2.31 ft/psi water conversion — see Methodology and the TDH calculator.
- Linsley, Kohler & Paulhus (1982), Hydrology for Engineers, 3rd ed., Table A-2 — water kinematic viscosity.
FAQ
Can I size my pump from the well depth?
No. The pump lifts from the pumping water level, which is usually much shallower than the bottom of the well. Total depth does not enter TDH.
Why does the calculator use the cut-out pressure?
The pump has to build pressure up to the cut-out setting for the switch to turn it off normally, so that is the highest pressure it must reach.
Will a bigger pump fix a low-yield well?
No. A larger pump cannot make the well produce more water than its sustainable yield. Storage or a different system design may be needed.
Does this tell me what horsepower pump to buy?
No. Horsepower does not determine whether a pump meets your duty point. Check the GPM and TDH against the manufacturer's pump curve.
My home isn't in the table.
Choose “Enter required flow directly” and enter a flow rate determined for your home. The calculator does not extend the published table.
Related calculators
Total Dynamic Head Calculator
Combine elevation, required pressure and system losses into the head your pump must produce.